Plant Quality
Assessment

On-site Diagnostics

On-site Diagnostics focuses majorly on assessing a plant's current health quality and understanding the necessary steps which need to be taken to optimise the plant’s performance. 

 

The aspects addressed during the study are: 

  • Estimate the reasons for underperformance in your plant

  • Identify the causes of degradation and nature of defects in the modules

  • Evaluate the health of your BoS (both civil and electrical)

  • Suggest possible and most feasible solutions to improve generation from your solar power plant

The major tests included in the diagnostics study are:

  • Drone and hand-held thermography of modules and other BoS components

  • Module and string IV curve measurement (for 1000V and 1500V system)

  • EL Image analysis

  • PR analysis

  • Visual inspection

  • Inverter measurements 

    • Inverter efficiency measurement

    • Inverter efficiency analysis (via data log)

    • Power quality analysis (Information of TDH and Harmonics)

    • Energy loss analysis

    • Components and phase sequence

    • Dips and swells of voltage and currents

  • Other inverter tests 

    • Earth Resistance test

    • PV array isolation resistance test

    • Soft start test

    • Automatic start stop test

    • LCD Display checking

    • Communication functioning inspection

    • Power factor test

    • Conversion Efficiency test

    • Nominal input and output test

    • Contactor contact point abnormal warning test

    • SPD test

    • Grid connection current harmonics test

    • Anti-islanding test

  • Transformers tests

    • Insulation resistance and polarity index

    • Capacitance and tan delta test

    • Dissolved Gas analysis (DGA) Test Methane, Ethane, Ethylene, Acetylene, Carbon-dioxide, Carbon monoxide, Hydrogen, Total Gas content, and BDV test

  • Insulation test, Earth resistance test and Structure coating

  • Soiling analysis

  • Basic review of O&M practices


 

Case Studies

01.

Root cause analysis for an EPC

Screen Shot 2021-03-04 at 3.14.05 PM.png
 
Screen Shot 2021-03-04 at 3.15.58 PM.png
 

Plant details: 10.8 MW in UP (2 years old)

The EPC was not able to meet generation guarantee leading to huge penalty

PV-D was appointed as a technical consultant to identify the root cause and suggest amendments to avoid penalties. 

Observations

  • Modules underperforming by 14%

  • 25-30% modules were found to have solder contact failures

  • 15-18% modules found to have cracks mostly due to improper module handling

  • Pyranometer not calibrated properly which led to reporting of approx 10% higher PR

  • Modules exposed to PID due to improper earth pit maintenance

Performance improvement measures

  • Increasing the DC side loading of the plant to increase generation

  • Filing for warranty claim for modules with solar contact failures

  • Improving maintenance practices for earth pits and cleaning cycle.


 

02.

Performance improvement through re-binning and PID reversal

Screen Shot 2021-03-04 at 3.55.31 PM.png
 

Plant details: 8 MW in Gujarat (6 years old)

Underperformance indicated by the client

PV-D was appointed to conduct the diagnostics study and identify the reasons behind it and list out necessary amendments to optimize the performance

Observations

  • Modules underperforming by 8.3%

  • Soiling losses found around 2.6%

  • 20% modules suffered from PID

  • Poor ventilation in the shaft reduced inverter efficiency by 2%

  • Other damages include corrosion and inter-table shadow losses

  • Overall 4% loss in revenue due to excess degradation

Performance improvement measures

  • 1.1% plant performance improved by reducing mis-match losses in the modules

  • Up to 80% power recovery in PID impacted modules by installing PID reversal box

  • 2% improvement in inverter efficiency through proper maintenance

  • Structural changes in the plant to remove tilt and shadow losses


 

03.

Modules frame buckling

Screen Shot 2021-03-30 at 12.25.04 PM.png
 

Plant details: 20 MWp plant in Rajasthan (7 years old)

Observations

  • EPC did not provide scope for expansion to the modules

  • As a result, the frame of the modules started bulging because of excessive heat in the region

Performance improvement measures

A preventive plan was shared with the client with root cause analysis

 

Remote Diagnostics

PV-D has integrated all the on-site parameters in its desktop to analyse and produce accurate and reliable results. This diagnostics is possible remotely which increases its utility.

 

Following analyses are possible with the help of remote diagnostics

  • Plant historical generation and performance analysis

  • PVSyst report interpretation and comparison of benchmark losses to actual losses

  • Inverter efficiency analysis

  • WMS data analysis

  • Breakdown analysis

  • PR analysis and temperature corrected PR

  • String monitoring data analysis

  • Module performance analysis

  • Energy Yield Assessment

  • Shadow analysis

Know more about our other services


 

Procurement and Construction Support

11.png

To assess the quality of modules and other BoS components to be installed in the plant, technical assessment at manufacturing, transportation and post-installation can be conducted. This ensures the reliability and quality of material used in the plant.

Technical Due Diligence

22.png

To analyze and estimate the OPEX, CAPEX and revenue generation from the solar asset under bidding, technical performance of the plant plays a crucial role. This study includes all the factors essential for understanding the technical aspects of the plant and its future revenue scope.